8 014 1 start up sheet tank
START-UP SHEET Furnace/ Duct/ Unit Heater
Job Name ____ Job Number ____
Job Address ____
Section 5: Equipment Description
| Spec. #: | Submittal #: | P&ID/Dwg #: |
|---|---|---|
| Area Served: |
| Data | Design | Actual On Site |
|---|---|---|
| Unit Tag # | ||
| Manufacturer | ||
| Model # | ||
| Serial # |
| Filter Description | Pre-Filter | Bag Filter | Final Filter |
|---|---|---|---|
| Type % Efficient | |||
| Size & Quantity | |||
| Size & Quantity |
| Belt Description | | | | | --- | --- | --- | | Size&Quantity | | | |
Section 6: Equipment Pre-Installation Inspection
| Step | Inspection Description | Yes | No | N/A | Performed By(Initials & Date) |
|---|---|---|---|---|---|
| 6.2 | Nameplate data matches vendor specifications. | $\Box$ | $\Box$ | $\Box$ | |
| 6.3 | All parts are received. | $\Box$ | $\Box$ | $\Box$ | |
| 6.4 | No visible signs of damage, leak, or defective parts. | $\Box$ | $\Box$ | $\Box$ |
Comments/ Observations
Performed (Therma)
By
Reviewed By
| Print Name | Signature | Date |
|---|---|---|
(Owner/Representatives)
Section 6: Further Inspections
| Step | Inspection Description | Yes | No | N/A | Performed By(Initials & Date) |
|---|---|---|---|---|---|
| 6.5 | Verify electrical service for correct voltage, current and thermal overload protection. | $\Box$ | $\Box$ | $\Box$ | |
| 6.6 | Operational and Maintenance(O&M) manual is available in field. | $\Box$ | $\Box$ | $\Box$ | |
| 6.7 | Start-up technicians have reviewed factory start-up procedures in O&M manual. | $\Box$ | $\Box$ | $\Box$ | |
| 6.8 | If Therma provided Variable Frequency Drives(VFDs) that are controlling the fans, complete FN 8.029.1 VFD start-up form(s). | ||||
| 6.9 | If Therma provided smoke fire dampers use FN(new form presently SFT-Test) | $\Box$ | $\Box$ | $\Box$ |
Section 7: Installation Inspection
| ID | Inspection Description | Yes | No | N/A | Performed By (Initials & Date) |
|---|---|---|---|---|---|
| 7.2 | Unit is installed level. | □ | □ | □ | |
| 7.3 | Tag # is attached to the unit. | □ | □ | □ | |
| 7.4 | Service clearance is adequate for maintenance. | □ | □ | □ | |
| 7.5 | Roof curb is installed to mate with the unit. | □ | □ | □ | |
| 7.6 | All access panels and covers are in place. | □ | □ | □ | |
| 7.7 | Vibration isolators are installed and adjusted. | □ | □ | □ | |
| 7.8 | Ductwork and flex connections are connected and sealed. | □ | □ | □ | |
| 7.9 | Economizer or outside air damper is installed. | □ | □ | □ | |
| 7.10 | All filters are in place and positioned properly. | □ | □ | □ | |
| 7.11 | Condensate drain and trap are installed. | □ | □ | □ | |
| 7.12 | Gas supply piping is installed. | □ | □ | □ |
Comments/
| Print Name | Signature | Date |
|---|---|---|
| Step | Inspection Description | Yes | No | N/A | Performed By (Initials & Date) |
|---|---|---|---|---|---|
| 7.13 | Gas supply piping has been checked for leaks. | □ | □ | □ | |
| 7.14 | Gas supply piping is bled of air. | □ | □ | □ | |
| 7.15 | Vent stack is proper height and size. | □ | □ | □ | |
| 7.16 | Unrestricted vent cap on top to protect from weather and down drafts. | □ | □ | □ | |
| 7.17 | Each fan drive belt tension is correct. | □ | □ | □ | |
| 7.18 | Sheaves are aligned. | □ | □ | □ | |
| 7.19 | Fan hub, sheaves, and bearing set-screws are tight. | □ | □ | □ | |
| 7.20 | Smoke detector is installed. | □ | □ | □ | |
| 7.21 | Motor and blower bearings are lubricated. | □ | □ | □ | |
| 7.22 | Electrical connections are secure. | □ | □ | □ | |
| 7.23 | Fan bearings angular alignment is correct and bolts are tight | □ | □ | □ | |
| 7.24 | Shipping blocks and materials are removed from fan section. | □ | □ | □ | |
| 7.25 | Thermostat is installed. | □ | □ | □ | |
| 7.26 | Time clock is installed. | □ | □ | □ | |
| 7.27 | Make-up water is installed. | □ | □ | □ |
| Print Name | Signature | Date |
|---|---|---|
Section 8: Operational Inspection
| Step | Inspection Description | Yes | No | N/A | Performed By(Initials & Date) |
|---|---|---|---|---|---|
| 8.2 | Unit vibration is acceptable. | $\Box$ | $\Box$ | $\Box$ | |
| 8.3 | Each fan rotation is correct. | $\Box$ | $\Box$ | $\Box$ | |
| 8.4 | Natural gas supply pressure is at manufacturer's specification. | $\Box$ | $\Box$ | $\Box$ | |
| 8.5 | Manifold pressure is at manufacturer's specification. | $\Box$ | $\Box$ | $\Box$ | |
| 8.6 | Heating components perform per manufacturer's specification. | $\Box$ | $\Box$ | $\Box$ | |
| 8.7 | Cooling components perform per manufacturer's specification. | $\Box$ | $\Box$ | $\Box$ | |
| 8.8 | VAV components perform per manufacturer's specification. | $\Box$ | $\Box$ | $\Box$ | |
| 8.9 | Economizer components perform per manufacturer's specification. | $\Box$ | $\Box$ | $\Box$ | |
| 8.10 | Smoke detector is tested and is able to shut the unit down. | $\Box$ | $\Box$ | $\Box$ | |
| 8.11 | Make sure thermostat is set. | $\Box$ | $\Box$ | $\Box$ | |
| 8.12 | Make sure time clock is set. | $\Box$ | $\Box$ | $\Box$ | |
| 8.13 | Fire dampers are functional and open | $\Box$ | $\Box$ | $\Box$ | |
| 8.14 | Supply, return and outside air dampers are functional | $\Box$ | $\Box$ | $\Box$ | |
| 8.15 | Record start up operating parameters in Supplementary Form(FN 8.028.2 or FN 8.028.3). |
End of Section
End of Section
Comments/ Observations
Performed By
Reviewed By
| Print Name | Signature | Date |
|---|---|---|
(Owner/Representatives)